淡江大學機構典藏:Item 987654321/94901
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 62830/95882 (66%)
造訪人次 : 4147148      線上人數 : 355
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/94901


    題名: 無機膜過濾蛋白質溶液之結垢現象與濾速回復
    其他題名: Membrane Fouling and Flux Recovery in Filtration of Protein Solutions by Inorganic Membrane
    作者: 鄭東文;李培銘
    貢獻者: 淡江大學化學工程與材料工程學系
    關鍵詞: 奈米過濾;薄膜結垢;蛋白質;濾速回復;Nanofiltration;Membrane fouling;Protein;Flux recovery
    日期: 2006-11
    上傳時間: 2014-02-09 00:39:36 (UTC+8)
    摘要: 本研究選用無機奈米薄膜,以連續式掃流過濾系統對蛋白質溶液進行過濾實驗,探討不同操作條件及溶液性質對濾速與薄膜結垢的影響,以尋求提升濾速之操作方式。首就蛋白質溶液於管式單通道無機薄膜過濾系統之濾速行為,討論操作參數(透膜壓差、濃度、pH值、掃流速度等)對濾速之影響,並定量薄膜結垢之阻力,找出適當之清洗方法。 結果顯示,NaOH溶液可有效清洗移除附著於膜上BSA之結垢,但隨著溶液濃度之增加也需提高NaOH清洗液之濃度。當操作流態為亂流時,BSA進料濃度對濾速之影響不大。在BSA與β-cyclodextrin的混合溶液系統中,薄膜對β-cyclodextrin之阻隔率隨溶液pH值不同而有所改變。以5k Da薄膜為例,當pH=6.87時,β-cyclodextrin之阻隔率高達80%,而當pH=10時,則有低於30%之阻隔率,這是因為BSA粒子形成之極化層緊密度不同所致。因此,選擇適當pH值可將BSA溶液中之小分子進行分離。
    In this study, the inorganic tubular membranes (1000, 5000 MWCO) were employed in a cross-flow filtration system to investigate the effects of operation conditions, solutions and membrane properties on protein solutions filtration. The ways for cleaning the membrane fouling were also discussed. The solution fluxes and solute rejections were measured under various operating parameters such as membrane MWCO, transmembrane pressure, pH value and solution composition. Experimental results indicate that the NaOH solution could remove the BAS fouling on the membrane and the required concentration of NaOH solution increases as the feed BSA concentration increases. Under the turbulent flow pattern, the increase in BSA concentration just slightly reduces the flux. For BSA and beta-cyclodextrin binary solution, the rejection of beta-cyclodextrin varies with the pH value. In the case of 5k Da membrane, the rejection of beta-cyclodextrin is higher than 80% at pH 6.87 and less than 30% at pH 10. This is due to the fact that the porosity of the polarization layer of BSA on the membrane surface varies with pH value. Therefore, the present membrane can be applied for the separation of small molecule from BSA solution by choosing a suitable pH value.
    關聯: 2006台灣化學工程學會第53屆年會:國科會化工學門成果發表研討會論文集,4頁
    顯示於類別:[化學工程與材料工程學系暨研究所] 會議論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    無機膜過濾蛋白質溶液之結垢現象與濾速回復_中文摘要.docx摘要18KbMicrosoft Word162檢視/開啟
    無機膜過濾蛋白質溶液之結垢現象與濾速回復_英文摘要.docx摘要17KbMicrosoft Word95檢視/開啟

    在機構典藏中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回饋