淡江大學機構典藏:Item 987654321/94364
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 62805/95882 (66%)
造访人次 : 3990919      在线人数 : 635
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/94364


    题名: 透析過濾操作中玻尿酸溶液之濾速行為及其純化
    其它题名: Flux behavior and purification of hyaluronic acid solution by using diafiltration
    作者: 王莉茹;Wang, Li-Lu
    贡献者: 淡江大學化學工程與材料工程學系碩士班
    鄭東文;Cheng, Tung-Wen
    关键词: 透析過濾;玻尿酸;純化;電解質;Diafiltration;Hyaluronic acid;Purification;Electrolyte
    日期: 2013
    上传时间: 2014-01-23 14:28:13 (UTC+8)
    摘要: 本實驗採用一透析過濾裝置進行實驗,以單成分HA溶液、單成分LY溶液以及HA/LY雙成分溶液為實驗對象,並採用批次恆壓型式,針對攪拌速度、電解質種類、電解質濃度、透析液體積、透析液電解質濃度等操作變數之改變進行實驗分析。
    研究結果顯示,加入攪拌可有效降低過濾阻力而提高濾速,電解質離子強度越大,使玻尿酸分子萎縮捲曲的程度越大,使得HA堆積形態越為緊密,濾速相對較低;而電解質造成LY與薄膜以及HA之間的靜電作用力降低,使LY不易吸附於膜面上,較易通過薄膜,提高移除效率。隨著透析過濾操作之進行,增加透析體積有助於批次濾出進料槽中之LY;若透析液中電解質濃增加有助於LY之移除率,但到達一定濃度後,再增加電解質濃度反而會影響LY的移除。
    In this study, the HA solution, LY solution and the mixture solution of HA/LY were used as the feed solution, and experimented by adopting diafiltration in a dead-end stirred cell. The experimented results were discussed under different operating conditions such as stirred rate, electrolyte type, electrolyte concentration and diavolumes.
    The results shows that the addition of stirring can reduce the filtration resistance and improve the permeate flux. The permeate flux decreases with the increase of ion strength of electrolyte which causes the HA molecules become more shrunken and then form a compact deposited layer on membrane surface. However, the LY molecules can pass through the membrane more easily as the electrolyte is added. The strength of electrode ion will hinder the surface charge of LY, and decrease the electrostatic interference between LY molecules and membrane. During the diafiltration process of HA/LY solution, the diavolumes and electrolyte concentration can increase the removal of LY. But there is a limit to the increase of electrolyte concentration in dialyate solution, instead, would decrease the removal of LY.
    显示于类别:[化學工程與材料工程學系暨研究所] 學位論文

    文件中的档案:

    档案 大小格式浏览次数
    index.html0KbHTML188检视/开启

    在機構典藏中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回馈