English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 62793/95819 (66%)
造访人次 : 3638150      在线人数 : 174
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/83729


    题名: A Transient HLLC type Incompressible Riemann Solver and Application on Aortic Flows Simulation
    作者: Niu, Yang-Yao;Chang, Chih-Hung;Tseng, Wen-Yih I.;Peng , Hsu-Hsia;Yu, Hsi-Yu
    贡献者: 淡江大學航空太空工程學系
    关键词: HLLC, Riemann solver, incompressible flow, aortic flow, fluid-structure interaction.
    日期: 2009-01
    上传时间: 2013-03-20 16:57:08 (UTC+8)
    出版者: Hong Kong: Global Science Press
    摘要: In this study, a three-dimensional artificial compressibility solver based on the average-state Harten-Lax-van Leer-Contact (HLLC) \cite{13} type Riemann solution is first proposed and developed to solve the time-dependent incompressible flow equations. To implement unsteady flow calculations, a dual time stepping strategy including the LU decomposition method is used in the pseudo-time iteration and the second-order accurate backward difference is adopted to discretize the unsteady flow term. Also a third-order accurate HLLC numerical flux is derived for approximating the inviscid terms. To verify numerical accuracy, flows over a lid-driven cavity and an oscillating flat plate are chosen as the benchmark tests. In addition, the current solver is extended to solve blood flows in a realistic human aorta measured from MRI (Magnetic Resonance Imaging). The simulation geometry was derived from a three-dimensional reconstruction of a series of two-dimensional slices obtained in vivo. Numerical results demonstrate wall stresses were highly dynamic, but were generally high along the outer wall in the vicinity of the branches and low along the inner wall, particularly in the descending aorta. The maximum wall stress distribution is presented on the aortic arch in the systole. In addition, extensive counter-clockwise secondary flows and three-dimensional helical vortex influenced considerably by the presence of vessel contraction, torsion and the branches were shown in the descending aorta in the late systole and early diastolic cycles.
    關聯: Communications in Computational Physics 5(1), pp.142-162
    显示于类别:[航空太空工程學系暨研究所] 期刊論文

    文件中的档案:

    档案 大小格式浏览次数
    index.html0KbHTML506检视/开启

    在機構典藏中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回馈