English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 49433/84396 (59%)
造訪人次 : 7468809      線上人數 : 67
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    請使用永久網址來引用或連結此文件: http://tkuir.lib.tku.edu.tw:8080/dspace/handle/987654321/78539

    題名: Correlation in Retinal Nerve Fiber Layer Thickness between two OCT Units
    作者: Chen, Hsin-yi;Chang, Yue-cune;Lane, Hsien-yuan
    貢獻者: 淡江大學數學學系
    關鍵詞: correlation;Stratus OCT;Cirrus OCT;Taiwan Chinese population
    日期: 2011-11
    上傳時間: 2012-10-11 19:10:25 (UTC+8)
    出版者: Philadelphia: Lippincott Williams & Wilkins
    摘要: Purpose. It is expected that spectral-domain optical coherence tomography (SD-OCT) will replace time-domain (TD)-OCT in the near future. In this study, we applied a robust set of statistical analyses to evaluate the correlation between retinal nerve fiber layer (RNFL) thickness measurements obtained by SD-OCT and those obtained by TD-OCT in a Chinese population with different stages of glaucoma.
    Methods. A total of 40 patients with primary open-angle glaucoma, 31 with primary angle-closure glaucoma (PACG), 31 with suspected glaucoma (GS), 25 with ocular hypertension (OH), and 52 normal subjects were enrolled in this prospective, cross-sectional study. Eyes of all participants were imaged by a single trained operator using the Stratus TD-OCT (fast RNFL scan mode) system and the Cirrus SD-OCT (optic disc cube mode) system during the same visit. The correlations between RNFL thickness measurements obtained from the two OCT instruments were assessed using Pearson correlation analysis and generalized estimating equation (GEE), mixed effect, linear regression models, after adjusting for the effect of individual variation.
    Results. There was good correlation in RNFL thickness parameters between the two OCT devices, particularly in average RNFL thickness (Pearson Correlation, 0.8798 vs. GEE mixed model, 0.9470). The proposed GEE mixed model method showed better correlation than the Pearson correlation analysis in each RNFL thickness parameter between the two OCT measurements.
    Conclusions. Although the RNFL thickness measurements obtained by the TD-OCT system correlated well with those obtained by the SD-OCT system, clinicians should be cautious when interpreting RNFL thickness data for any subject undergoing longitudinal follow-up with different OCTs.