淡江大學機構典藏:Item 987654321/74145
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 62830/95882 (66%)
造访人次 : 4037009      在线人数 : 593
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/74145


    题名: 利用原子力顯微術對腸病毒71型病毒顆粒進行微結構與力學性質之研究
    其它题名: Studies of surface ultrastructure and mechanical property of enterovirus 71 virions by atomic force microscopy
    作者: 鄭宇翔;Cheng, Yu-Hsiang
    贡献者: 淡江大學化學學系碩士班
    李世元;Lee, Adam Shih-Yuan
    关键词: 原子力顯微術;腸病毒71型;解離力;Atomic force microscopy;Enterovirus 71;Unbinding force
    日期: 2011
    上传时间: 2011-12-28 18:09:40 (UTC+8)
    摘要: 在此篇研究中,我們使用原子力顯微術(AFM)去研究腸病毒71型的表面型態與奈米結構,高解析度的影像可直接針對臨床檢體及培養之病毒進行觀察與定量量測。此外,本論文也利用原子力顯微術來測量抗體探針與固定化在基質上的病毒之間解離力,藉由腸病毒71型抗體抗原專一性的力-距離曲線圖形,可觀察到單一、雙重、多重性的解離事件,可能因單一或連續多重的交互作用力被打斷所造成的影響。以拉離速度166.7 nm/s的量測條件下,腸病毒患者與正常人樣本的解離力分別為300.5±92.24 和 25.24±7.76 pN。研究結果呈現出以AFM作為力學感測器,可快速及靈敏的鑑別腸病毒患者與正常人之檢體。因此,在未來的臨床診斷上,可應用原子力顯微術可做為臨床之生物感測器。
    In this study, the morphology and nanostructure of enterovirus type-71 were studied by atomic force microscopy (AFM). The enterovirus type-71 virus from cell culture and clinical sample were directly visualized and quantitative measurements. Moreover, AFM was used to measure the unbinding force between antibody probe and virus coated on the substrate surface. Force-distance curves of a specific enterovirus type-71/anti-enterovirus type-71 interaction system with mono-, di-, and multi-unbinding events were recorded, which may be attributed to a single, sequential or multiple breaking of interacting bond(s) between enterovirus type-71–anti-enterovirus type-71. For each unbinding force measurement at a pulling velocity of 166.7 nm/s, the mean value of the clinical sample (EV122) and normal sample (C1-2,M-11-T ) are 300.5±92.24 and 25.24±7.76 pN respectively.
    This result demonstrated that the enterovirus type-71 in clinical sample could be measured and discriminated form normal sample by a force–based AFM biosensor. The use of AFM can be a rapid and sensitive method in the development of a clinical cantilever-based mechanical biosensor.
    显示于类别:[化學學系暨研究所] 學位論文

    文件中的档案:

    档案 大小格式浏览次数
    index.html0KbHTML243检视/开启

    在機構典藏中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回馈