淡江大學機構典藏:Item 987654321/71206
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 62830/95882 (66%)
Visitors : 4045643      Online Users : 859
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/71206


    Title: 逆洗與通氣對管式薄膜過濾蛋白質溶液濾速增進之探討
    Other Titles: Flux Enhancement by Backwashing and Gas-sparging in Tubular Membrane Filtration of Protein Solution
    Authors: 鄭東文;Cheng, Tung-wen;鄭運馨;Cheng, Yun-hsin
    Contributors: 淡江大學化學工程與材料工程學系
    Keywords: 薄膜過濾;逆洗;通氣;結垢;Membrane filtraton;BSA;Back washing;Gas-sparging;Fouling
    Date: 2008
    Issue Date: 2012-12-03 23:30:08 (UTC+8)
    Publisher: 臺北市:行政院國家科學委員會
    Abstract: 本研究以掃流式無機薄膜過濾系統探討在不同操
    作方法及操作參數下之蛋白質溶液過濾行為與結垢現
    象,實驗溶液為BSA,操作參數有透膜壓差、濃度、pH值、液體速度、氣體速度及逆洗頻率等。實驗結果顯示,
    pH 值為3時濾速最高、pH 值為7 時次之、pH 值為4.9
    時濾速最低,由於濃度極化層的阻力與BSA 之電性及
    形狀有關,pH值為3時BSA 為帶狀且表面帶電,濃度
    極化層不易堆積,因此濾速最高,pH 值為4 . 9 時, BSA
    為球狀且表面不帶電,因此所形成之濃度極化層最緻
    密,使得濾速最低。而由不同操作方式之淨濾速分析可
    知,通氣為最佳的操作方式,逆洗會因清洗耗去的港、液
    量而使濾速低於一般過濾。通氣可移除濃度極化層,防
    止BSA 粒子吸附於且其面,且不需耗費濾液清洗,因此
    具有最高的淨濾速, pH 值為3 時,通氣約可提高60
    %之濾速。In this study, the inorganic membranes were
    employed in a cross-flow filitration system to discuss the
    flux and fouling behavior of protein solutions under
    various solution properties and operating parameters to
    search the manner for increasing the flux. BSA was
    selected as the testing solution and the operating
    parameters such as transmembrane pressure, solution
    concentration, pH value, liquid velocity, air velocity and
    back washing frequency. For varying the pH, the
    experimental results show that the permeate flux is
    maximum at pH=3 and is minimum at pH =4.9. The BSA
    particle's shape and surface charge were determined by the
    pH value. At pH=3, the BSA molecules are linear with
    surface charge, the BSA polarization layer in the filtration
    has a loose structure results in a lower filtration resistance.
    At pH = 4.9, a compact BSA polarization layer's structure
    was formed due to the neutral and nearly spherical BSA
    molecues. Basing on the analysis of net permeate flux, the
    gas sparging method is better than the backwashing for
    flux enhancement. The gas sparging can effectively
    remove the polarization layer and reduce the BSA
    deposition on the membrane. Furthermore, no permeate is
    wasted for washing in gas sparging. At pH =3, the flux
    increment by gas sparging is up to 60%.
    Relation: 2008年輸送現象及其應用研討會論文摘要集 ( 2008 Symposium of transport phenomena and applications abstract book)
    Appears in Collections:[Graduate Institute & Department of Chemical and Materials Engineering] Proceeding

    Files in This Item:

    File SizeFormat
    index.html0KbHTML230View/Open

    All items in 機構典藏 are protected by copyright, with all rights reserved.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - Feedback