淡江大學機構典藏:Item 987654321/60407
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 62805/95882 (66%)
造访人次 : 3987921      在线人数 : 615
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/60407


    题名: Separation of protein from suspended particles using submerged membrane filtration
    作者: Hwang, Kuo-Jen;Lo, Hung-Pin;Cheng, Tung-Wen;Tung, Kuo-Lun
    贡献者: 淡江大學化學工程與材料工程學系
    关键词: Microfiltration;Membrane fouling;Submerged membrane filtration;Filtration resistance;Protein separation
    日期: 2010-10-01
    上传时间: 2011-10-13 22:39:04 (UTC+8)
    出版者: Amsterdam: Elsevier BV
    摘要: In this study, bovine serum albumin (BSA) molecules are separated from suspended particles using submerged membrane filtration. Several methods, including constant-pressure filtration with backwash, air bubble sparging and a stepwise increase in pressure, are used to reduce filtration resistance and to enhance filtration flux. The effects of filtration pressure, backwash flow rate, backwash duration, air flow rate and stepwise pressure increase on filtration flux, filtration resistances, BSA rejection and BSA production are discussed. The results show that internal fouling of the filter membrane is the most important contributor to the overall filtration resistance, while cake formation is the main determinant of BSA rejection. An increase in filtration pressure leads to lower filtration flux and lower BSA rejection due to more severe internal fouling of the membrane. Although additional periodic backwash or air bubble sparging increases the filtration flux relative to solely constant-pressure filtration, the filtration flux and BSA production when using a stepwise pressure increase is much higher than with the other operations, especially when the latter is combined with a periodic backwash. Moreover, the calculated filtration flux and BSA rejection results for constant-pressure filtration under various filtration pressures agree fairly well with experimental data.
    關聯: Journal of Membrane Science 362(1-2), pp.427-433
    DOI: 10.1016/j.memsci.2010.06.051
    显示于类别:[化學工程與材料工程學系暨研究所] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    0376-7388_362(1-2)p427-433.pdf557KbAdobe PDF270检视/开启
    0376-7388_362(1-2)p427-433.pdf557KbAdobe PDF2检视/开启

    在機構典藏中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回馈