淡江大學機構典藏:Item 987654321/54235
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 62822/95882 (66%)
Visitors : 4020070      Online Users : 940
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/54235


    Title: Improvement of Pulse Amperometric Detection Integrated Automated Flow Injection Analysis of Ethylenethiourea Determination
    Authors: 林孟山;王俊勝;陳佩彥;葉秀炫
    Contributors: 淡江大學化學學系
    Keywords: Pulse amperometric detection;Ethylenethiourea;Automated flow injection analysis
    Date: 2004-12-01
    Issue Date: 2013-07-29 13:48:01 (UTC+8)
    Publisher: 臺北市:中國化學學會
    Abstract: Improvement of pulse amperometric detection (PAD) method is demonstrated in determination of ethylenethiourea (imidazolidine-2-thione, ETU). The anodic detection of ETU will produce polymeric film on an electrode leading to an inactive electrode surface. Here, the PAD method was used to remove the polymeric film formed on the electrode surface between ETU detection. Further, the scheme was integrated with automated flow injection analysis (AFIA) for determining ETU. The operational parameters of PAD in the AFIA system were discussed thoroughly. The analytical characteristics of the system were evaluated at optimum conditions. The linear range of calibration plot was between 20 to 300 μM (the correlative coefficient, r = 0.999) and the detection limit was 0.9 μM (S/N = 3). The relative standard deviations of detection of 50μM ETU were 0.82% with and 9.07% without PAD scheme. The results indicate the system is a very promising tool for ETU determination. Finally, the matrix effects of two water samples that were collected from a campus and a farm show good recoveries of 92% and 96%.
    Relation: Journal of the Chinese Chemical Society=中國化學會會誌 51(6), pp.1293-1296
    DOI: 10.1002/jccs.200400187
    Appears in Collections:[Graduate Institute & Department of Chemistry] Journal Article

    Files in This Item:

    File SizeFormat
    index.html0KbHTML212View/Open

    All items in 機構典藏 are protected by copyright, with all rights reserved.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - Feedback