淡江大學機構典藏:Item 987654321/52464
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 62830/95882 (66%)
Visitors : 4049440      Online Users : 819
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/52464


    Title: 超音波晶體乳化手術併人工水晶體植入於隅角閉鎖型青光眼治療之研究
    Other Titles: Phacoemulsification with intraocular lens implantation of posterior chamber in angle-closure glaucoma therapy
    Authors: 蕭天偉;Hsiao, Tian-wei
    Contributors: 淡江大學機械與機電工程學系碩士班
    李宗翰;Lee, Tzung-hung;黃曼菁;Huang, Man-ching
    Keywords: 超音波晶體乳化手術;隅角閉鎖型青光眼;眼壓;Angle-closured glaucoma;Phacoemulsification;Pressure
    Date: 2010
    Issue Date: 2010-09-23 17:49:31 (UTC+8)
    Abstract: 由於近年來臨床手術上採用超音波晶體乳化手術來治療隅角閉鎖型青光眼效果卓越。故我們針對超音波晶體乳化手術的術前與術後進行模擬。超音波晶體乳化手術是利用超音波破壞或乳化混濁的水晶體變成細小的碎片再將其移除,並置入人工水晶體的一種手術。
    本研究主要是以數值模擬的方法,來探討超音波晶體乳化手術用於治療隅角閉鎖型青光眼術後於眼球前後房及玻璃體外部的壓力分布狀況,藉以比較手術前後壓力變化差異。
    根據本研究所模擬出來的結果,經過超音波晶體乳化手術後,由術前的40~49mmHg降低至12~15mmHg,並與正常人的眼壓相較也降低了28%,與國外臨床量測相似,並且模擬術前與術後的眼內壓力傳遞情形,此研究在臨床量測上是難以做到的,藉此研究讓醫師做為使用超音波晶體乳化手術做為隅角閉鎖型青光眼的第一線治療的依據。
    Clinical surgery in recent years adopted phacoemulsification surgery for the treatment of angle closure glaucoma effects of Excellence . Therefore, we focused on phacoemulsification surgery performed before and after the simulation. Phacoemulsification surgery is the use of ultrasound destruction or emulsification cloudy lens into tiny pieces then remove it , and an intraocular lens implantation surgery .
    This study is based on numerical simulation to explore the phacoemulsification surgery for the treatment of angle closure glaucoma before and after surgery in the eye and vitreous room distribution of external pressure to compare the pressure difference before and after surgery .
    Simulated according to the results of this study , after phacoemulsification surgery by preoperative 40 ~ 49mmHg reduced to 12 ~ 15mmHg, with normal intraocular pressure is also reduced by 28% compared with the amount of foreign clinical Test similar , and simulation of preoperative and postoperative intraocular pressure transmission case , this study on the clinical measurement is difficult to do , to study for physicians to use phacoemulsification surgery as angle closure glaucoma as a first line of Treatment basis.
    Appears in Collections:[Graduate Institute & Department of Mechanical and Electro-Mechanical Engineering] Thesis

    Files in This Item:

    File SizeFormat
    index.html0KbHTML243View/Open

    All items in 機構典藏 are protected by copyright, with all rights reserved.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - Feedback