淡江大學機構典藏:Item 987654321/35934
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 62805/95882 (66%)
Visitors : 3934685      Online Users : 745
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/35934


    Title: 零價鐵去除水中硝酸鹽之研究
    Other Titles: Nitrate removal by zero-valent iron (ZVI)
    Authors: 陳一銘;Chen, Yi-ming
    Contributors: 淡江大學水資源及環境工程學系博士班
    李奇旺;Li, Chi-wang
    Keywords: 硝酸鹽;pH;零價鐵;回收率;流體化反應器;nitrate;pH;ZVI;N-recovery;fluidize
    Date: 2007
    Issue Date: 2010-01-11 07:22:05 (UTC+8)
    Abstract: 本論文成功結合零價鐵與流體化技術發展出零價鐵流體化反應器、雙流體化反應系統以及加壓式零價鐵流體化反應器等三種處理程序應用於水中硝酸鹽之處理。以下分三部份說明之。
    零價鐵流體化反應器
    本實驗採用零價鐵流體化反應器還原硝酸鹽,本系統可有效控制適合硝酸鹽反應之pH值,在水力停留時間15 min,其硝酸鹽去除率隨著初始ZVI劑量的增加而增加,在ZVI為33.3 g l-1時,在pH值未控制時,去除率為13 %;而pH值4.0時去除率則上升到92 %,而當pH值控制在4.0時,水力停留時間縮短至3 min時去除率還有87 %,在氮回收率方面,在pH4.0時約只有50 %,而pH值未控制則有100%,而實驗中以証明排除硝酸鹽或氨吸附於氧化鐵上所造成的可能性,因此推測在pH值4.0之下反應是有可能有含氮氣體產生。
    雙流體化反應系統
    本實驗系統由兩組流體化反應器所組成,其中第一反應器控制pH值加速反應效率,第二反應器則是以中和pH值為目的。由實驗結果可知,其出流水之pH值、硝酸鹽之去除率及其分流效果均有相當好的成效,其中第二反應器在無任何pH值控制系統下可不藉由任何的鹼液的加入,將處理之出流水pH值調整至中性範圍,其出流水之硝酸鹽出流濃度會隨BPR之增加而增加,而ZVI表面分析上,於pH4.0的實驗中,並未鑑定出Fe0之外的物種,而在pH8.5之實驗中,則分別鑑定出Fe2O3以及Fe3O4兩種之鐵氧化物,在氮回收率不足之問題上,本實驗採集反應時之氣態物質,進行定性分析,分析結果發現有反應時確實有氮氣之產生,因此在本系統中氮回收率不足之原因乃是含氮氣態產物生成所致。
    加壓式零價鐵流體化反應器
    本實驗採用零價鐵流體化反應器以CO2加壓來控制硝酸鹽反應時之pH值,且此系統可比曝氣系統大量減少CO2之用量且快速平衡pH值,實驗中發現,pH值會隨著反應時間增加而增加,而其硝酸鹽去除率效率將隨著減少,而整體去除率將隨著起始ZVI劑量的增加而增加,但在8.25 g l-1以上便趨於穩定,而初始硝酸鹽濃度增加至100 mg l-1時,對去除率只有些微的影響,而氮回收率方面實驗結果不若先前強酸控制pH值系統之結果,在各條件下均有100%之回收率,有可能是ZVI與硝酸鹽在不同pH值控制方式下有不同之反應路徑。
    Zero-valent iron (ZVI) and fluidize technique was successfully integrated in this study for nitrate removal, with three related processes developed, namely fluidized zero valent iron reactor, two fluidized ZVI reactors system, and pressurized CO2/zero valent iron system. Each of these is elaborated in the following three sections.
    Fluidized zero valent iron bed reactor
    With fluidized zero valent iron reactor, the pH of solution can be maintained at optimal conditions for rapid nitrate reduction. For hydraulic retention times of 15 min, the nitrate reduction efficiency increases with increasing ZVI dosage. At ZVI loadings of 33 g l-1, results indicate that the nitrate removal efficiency increases from less than 13% for systems without pH control to more than 92% for systems operated at pH of 4.0. By maintaining pH at 4.0, we are able to decrease the hydraulic retention time to 3 min and still achieve more than 87% nitrate reduction. The recovery of total nitrogen which is defined as the total of nitrate, ammonium, and nitrite was less than 50% for the system operated at pH 4.0, and was close to 100% for a system without pH control. The possibility of nitrate and ammonium adsorption onto iron corrosion products was ruled out by studying the behavior of their adsorption onto freshly hydrous ferric oxide at various pHs, suggesting the probable formation of nitrogen gas species during reaction in pH 4.0.
    Two fluidized ZVI reactors system
    A two fluidized ZVI reactors system was proposed to treat nitrate-contaminated water. The first column was employed to achieve an efficient nitrate reduction, while the second column was installed as the post-treatment process for neutralizing the effluent pH. The results of experiment show the pH increases and total nitrate removal decreases with increasing by pass ratio (BPR). Results from XRD analyses of the used ZVI taken from conditions at pH4.0 and 8.5 indicate only metallic iron was identified under pH4.0 condition and Fe2O3 and Fe3O4 along with metallic iron were identified for pH 8.5. Regarding to N-recovery deficiency problem, gaseous product was collected and nitrogen gas produced was confirmed.
    Pressurized CO2/zero valent iron system
    A fluidized zero valent iron reactor pressurized by CO2 gas for pH control was employed for nitrate reduction. The proposed CO2 pressurized system has advantages of using less CO2 gas and reaching equilibrium pH faster than CO2-bubbled system. However, due to weak acid nature of carbonic acid, system pH gradually increased with increasing oxidation of ZVI and reduction of nitrate. As pH increased with progress of reaction, nitrate removal rate decreased continuously. The results indicate that nitrate removal efficiency increases with increasing initial ZVI dosage but reaches plateau at ZVI doses of higher than 8.25 g l-1, and initial nitrate concentration up to 100 mg l-1 as N has minimal impact on the removal efficiency. Unlike the fluidized system with pH control by strong acid reported in our pervious study, near 100% of nitrogen recovery was observed in the current process, indicating that nitrate reduction by ZVI with different pH controlled mechanisms will have different reaction routes.
    Appears in Collections:[Graduate Institute & Department of Water Resources and Environmental Engineering] Thesis

    Files in This Item:

    File SizeFormat
    0KbUnknown237View/Open

    All items in 機構典藏 are protected by copyright, with all rights reserved.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - Feedback