淡江大學機構典藏:Item 987654321/25041
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 62819/95882 (66%)
造访人次 : 4007261      在线人数 : 576
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/25041


    题名: Measurement of dimensions of pentagonal doughnut-shaped C-reactive protein using atomic force microscopy and dual polarisation interferometry
    作者: 李世元;Lee, Adam Shih-yuan;Lin, Shiming;Lee, Chih-kung;Wang, Yu-ming;Huang, Long-sun;Lin, Yin-hang;Sheu, Bor-ching;Hsu, Su-ming
    贡献者: 淡江大學化學學系
    日期: 2006-09
    上传时间: 2009-12-01
    出版者: Elsevier
    摘要: In order to develop the C-reactive protein (CRP) sensor chips for clinical detection of atherosclerosis and coronary heart disease, we used an atomic force microscope (AFM) and a dual polarization interferometric (DPI) biosensor to probe the surface ultrastructure and to measure the dimensions of CRP. A single pentagonal structure was directly visualized by AFM, and quantitative measurements of the dimensions of the protein were provided. The average height calculated for each pentagonal CRP particle was approximately 3.03+/-0.37 nm, which basically corresponds to that (36 A in protomer diameter) previously obtained from the structure of CRP determined by X-ray crystallography. Moreover, a experiment using dual polarization interferometric (DPI) as a biosensor was then performed, and the average monolayer thickness value (3.18+/-0.43 nm) that was calculated basically corresponds to that obtained from the experimental value (3.03+/-0.37 nm) of the height measured by an AFM method for CRP. Further investigations will be performed to study the surface ultrastructure of a single pentagonal CRP molecule, and for this purpose a CRP sample (at low concentration) was scanned in vacuum by AFM. The higher-resolution images clearly revealed the presence of doughnut-shaped CRP molecules. In addition, phase images of CRP molecules were captured simultaneously with their height images, and the lateral dimensions of the doughnut-shaped CRP molecules were then measured. It was found that the average values calculated for the outer diameter (11.13+/-1.47 nm) and pore diameter (3.52+/-0.42 nm) are respectively close to those (102 A in outer diameter and 30 A in pore diameter) previously obtained from the structure of CRP determined by X-ray crystallography. This study represents the first direct characterization of the surface ultrastructure and dimensional measurement of the CRP molecule on the sensor chip.
    關聯: Biosensors and Bioelectronics 22(2), pp.323-327
    DOI: 10.1016/j.bios.2006.01.018
    显示于类别:[化學學系暨研究所] 期刊論文

    文件中的档案:

    档案 大小格式浏览次数
    index.html0KbHTML34检视/开启

    在機構典藏中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回馈