    题名: The influence of recycle on a parallel-plate heat exchanger with insulation sheet inserted for double-pass operations
    作者: Ho, Chii-dong;Yeh, Ho-ming;Lu, C. H.;Chiang, Su-ching
    贡献者: 淡江大學化學工程與材料工程學系
    日期: 2001-05
    上传时间: 2009-11-04 15:52:32 (UTC+8)
    出版者: Kidlington: Pergamon Press
    摘要: The influence of recycle on a parallel-plate heat exchanger of inserting in parallel an insulation sheet to divide an open duct into two channels for double-pass operations with uniform wall temperature has been studied analytically. The results are represented graphically and compared with those in an open duct (without an inserted insulation sheet) and a double-pass without recycle. Substantial improvement in heat transfer is obtainable by employing such a double-pass device with external refluxes, instead of using an open conduit with single-pass operations and using double-pass operations without recycle. The effect of insulation-sheet location on the enhancement of heat transfer efficiency as well as on the increment of power consumption, has been also discussed.
    關聯: International Communications in Heat and Mass Transfer 28(4), pp.527-536
    DOI: 10.1016/S0735-1933(01)00258-5
    显示于类别:[化學工程與材料工程學系暨研究所] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    0735-1933_28(4)p527-536.pdf482KbAdobe PDF303检视/开启