淡江大學機構典藏:Item 987654321/120684
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 62805/95882 (66%)
造访人次 : 3923038      在线人数 : 494
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/120684


    题名: Highly sensitive distance-based liquid crystalline visualization for paper-based analytical devices
    作者: Khachornsakkul, K.;Chang, J.-J.;Lin, P.-H.;Lin, Y.-H.;Dungchai, W.;Chen, C.-H.
    关键词: Bilirubin;Liquid crystal;Ultrasound;Distance-based sensors;Paper-based sensors
    日期: 2021-02-18
    上传时间: 2021-04-30 12:10:43 (UTC+8)
    出版者: Elsevier
    摘要: We successfully report on the first demonstration of a highly sensitive distance-based liquid crystalline visualization for paper-based analytical devices. The construction of this paper sensor was achieved by immobilizing 4-cyano-4′-pentylbiphenyl (5CB) as liquid crystalline molecules (LCs) onto a paper strip substrate. The sensing mechanism is based on the ultrasound-assisted decomposition of 5CB by the hydroxyl radical (•OH) which is generated from the oxidase enzymatic reaction of the analyte, this then results in the change of texture and color of paper. The utility of our devices was then demonstrated with the determination of bilirubin (BR) in biological samples using a bilirubin oxidase enzymatic reaction. The quantification of BR can be achieved by dipping the tip of the paper strips into the analyte solutions and then by measuring the length of color which has been changed on the paper, by the naked eye. Under optimized conditions, this paper sensor offered the linear range of BR detection from 2.0 to 30.0 pmol/L (R2 = 0.9945) with the limit of detection (LOD) of 0.80 pmol/L. In addition, the results of this sensor were highly reproducible, with a relative standard deviation (RSD) of less than 3.50%. The recoveries of spiked BR in human urine and serum samples were in the range of 99.09–107.89%, which demonstrates the high accuracy of this paper sensor. Overall, this work presents a simple method to determine the concentration of H2O2 and BR at pmol levels with an instrument-free length-measuring readout, so it could be suitable for quantitative analysis of other biomarkers based on oxidase enzymatic reaction, which can provide important information about early disease diagnosis and patient prognosis.
    關聯: Analytica Chimica Acta 1154, 338328
    DOI: 10.1016/j.aca.2021.338328
    显示于类别:[化學學系暨研究所] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML114检视/开启

    在機構典藏中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回馈