淡江大學機構典藏:Item 987654321/119068
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 62805/95882 (66%)
造访人次 : 3908069      在线人数 : 605
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/119068


    题名: Wind load reduction effects on inner buildings by exterior porous façades
    作者: Yuan-Lung Lo;Yu-Ting Wu;Chung-Lin Fu;Ying-Chang Yu
    关键词: Exterior porous façade;Wind pressure;Porosity percentage;Façade gap;Porous opening shape
    日期: 2020-08-04
    上传时间: 2020-09-17 12:11:35 (UTC+8)
    摘要: Modern architects often adopt the use of façades on new buildings or to improve the appearance of an existing old building. Among various types of facades, ones with porous skins are increasingly popular. The porous features can not only improve the aesthetic of design but can also significantly lower wind loads on the inner building. This research investigates the filtering performance of various exterior porous façades on the surface pressures of an ordinary building based on systematical wind tunnel tests. Three target parameters, the porosity percentage of the façade, the gap distance between the façade and the building surface, and the opening shape of the pores, are investigated in this study. Preliminary results show that the Reynolds number makes little difference to the measured mean and root-mean-square values of fluctuating pressures. Subsequent results show that the façade skin porosity and gap distance together contribute to any amplification or reduction of surface pressures measured on the inner building. Different reduction or amplification levels are also found highly related to the upstream or downstream region over the side faces for the mean and the fluctuating pressures. For a limited area near the building corners, an amplification in negative local pressures was found due to the flow entering the façade cavity on the windward face and being channeled between the façade and sidewall of the building. A channel-effect phenomenon is also indicated with the presence of the exterior skin in certain regions, instead of just the reducing effect from the pores.
    關聯: Building and Environment 183, 107148
    DOI: 10.1016/j.buildenv.2020.107148
    显示于类别:[建築學系暨研究所] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML99检视/开启

    在機構典藏中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回馈