淡江大學機構典藏:Item 987654321/118851
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 62805/95882 (66%)
造訪人次 : 3938313      線上人數 : 906
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/118851


    題名: A charge accumulation-free voltage-controlled functional electrical stimulator with bi-phasic sinusoidal stimulation
    作者: Wei-Hsien Chen;Chia-Hung Chang;Horng-Yuan Shih;Tzai-Wen Chiu;Chien-Nan Kuo
    關鍵詞: Bioelectronics;Charge accumulation-free;Voltage-controlled;Functional electrical stimulator;Bi-phasic;Sinusoidal
    日期: 2019-02-09
    上傳時間: 2020-07-06 12:10:14 (UTC+8)
    摘要: This paper presents a charge accumulation-free voltage-controlled (VC) bi-phasic sinusoidal functional electrical stimulator (FES) for bioelectronic application. Traditionally, constant current (CC) pulse-shaped FESs with active or passive charge balancers are used to compensate for accumulated charges arise from process, voltage and temperature (PVT) variation as a result of long-term stimulation. Unlike the CC pulse-shaped FES, the VC sinusoidal-shaped FES is adopted here to avoid charge accumulation over time. The charge balancer is not required, substantially reducing system complexity and the chip area of the FES. To demonstrate the feasibility of concept, in this paper, four channels of VC bi-phasic sinusoidal-shaped FESs are integrated with the bio-potential recording circuit to compare with four channels of CC bi-phasic pulse-shaped FESs that are integrated with the same neural recording system for comparison. Measurements indicate an absence of charge accumulation as a result of the VC FESs. In addition, here we adopt the sinusoidal stimulation to reduce transient effects on tissue in comparison to a pulse-shaped method. The bio-potential activities of a cockroach leg that is stimulated for 50 s by the proposed bi-phasic sinusoidal stimulation are recorded. The measured bio-potential activities of a cockroach leg show that no stimulation-evoked leg movement occurs under stimulation by the sinusoidal waveform.
    關聯: Analog Integrated Circuits and Signal Processing 101, p.331–339
    DOI: 10.1007/s10470-019-01417-x
    顯示於類別:[電機工程學系暨研究所] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML48檢視/開啟

    在機構典藏中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回饋