English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 62805/95882 (66%)
造访人次 : 3983763      在线人数 : 514
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/118702


    题名: Quantitative analysis of liquid crystal-based immunoassay using rectangular capillaries as sensing platform
    作者: Huang, Jhih-Wei;Hisamoto, Hideaki;Chen, Chih-Hsin
    日期: 2019-06-03
    上传时间: 2020-06-01 12:14:37 (UTC+8)
    摘要: In past studies, liquid crystal (LC)-based immunoassays were accomplished by fabricating an LC cell with two pieces of glass slides after immunobinding, which makes the determination of the immunoassay not in real-time and requires trained personnel. Herein, we developed the LC-based immunoassay by using rectangular capillaries as the substrate for immunobinding. The inner surface of rectangular capillaries was decorated with a long alkyl saline, dimethyloctadecyl[3-(trimethoxysilyl)propyl]ammonium chloride (DMOAP), followed by immobilization of human serum albumin (HSA) as the probe. In this situation, the orientation of LC was homeotropic and dark LC image was observed under polarized light. When the solution containing anti-human serum albumin (anti-HSA) were dispensed into the capillary through capillary action, the specific immunobinding between HSA and anti-HSA formed an immunocomplex on the inner surface of capillary, which disrupted the original orientation of LC and led to a dark-to-bright transition of the LC images. The quantification of anti-HSA can be achieved by measuring the length of the bright LC image in the rectangular capillary. By using this immunoassay, the limit of detection (LOD) for anti-HSA is 1 μg/mL, and it did not respond to HSA and anti-human immunoglobulin G (anti-h-IgG). On the other hand, the diversity of the LC-based immunoassay can be extended for HSA detection when we immobilized anti-HSA in the capillary. Because the post-fabrication of LC cell was waived by using rectangular capillaries to develop the LC-based immunoassay, it is more convenient for users to handle and collect more reliable data. Moreover, the results of the immunoassay were visualized through naked-eye and could be recorded by a smartphone; it is more suitable for portable and point-of-care applications.
    關聯: Optics Express 27(12), p.17080-17090
    DOI: 10.1364/OE.27.017080
    显示于类别:[化學學系暨研究所] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML68检视/开启
    Quantitative analysis of liquid crystal-based immunoassay using rectangular capillaries as sensing platform.pdf3605KbAdobe PDF76检视/开启

    在機構典藏中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回馈