淡江大學機構典藏:Item 987654321/117514
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 62805/95882 (66%)
造访人次 : 3989114      在线人数 : 576
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/117514


    题名: A computational investigation of atrial fibrillation treatment using HIFU energy source
    作者: Huang, Huang-Wen;Hui, Lin;Chen, Yung-Hui;Cheng, Yu Hsiang
    关键词: atrial fibrillation, HIFU (high intensity focused ultrasound), heart rhythm disorder, computer simulation, Pennes’ Bioheat Transfer equation.
    日期: 2019-07-09
    上传时间: 2019-10-22 12:11:04 (UTC+8)
    摘要: Atrial fibrillation (AF) is the most prevalent arrhythmia of the heart, originating usually from ectopic atrial activity of the pulmonary veins. In recent technology, RF ablation has been part of clinical practice for more than two decades and has become an important treatment option for most clinically relevant cardiac arrhythmias [1]. The electrical isolation by ablation of the pulmonary veins (PVs) in the left atrium (LA) of the heart has been proven as an effective cure of atrial fibrillation (AF). The advantage of HIFU is that it could cause deep tissue lesions without damaging intervening tissues and prevent from thrombosis. Thus, it may lead to reducing the risk of stroke. The computer model uses the Pressure Acoustics, Frequency Domain interface to model the stationary acoustic field. The wave equation solved is the homogeneous Helmholtz equation in 2D axisymmetric cylindrical coordinates. With calculated acoustic pressure field, the generated heat combines with the Pennes’ Bioheat Transfer equation to solve the temperature field. The use of extracorporeal HIFU ablation has a problem of vibration motion of heart and it causes focal energy unfocused. The results showed the impact of the thickness of traversing medium to the focal area and heating power with pulse time on the focal area. The varying thickness is to simulate vibration of heart motion. Frequency ranging from 1 MHz to 4 MHz and different geometrical configurations are studied. The preliminary computer modeling and test are feasible. There are in consistent.
    显示于类别:[資訊創新與科技學系] 會議論文

    文件中的档案:

    档案 大小格式浏览次数
    index.html0KbHTML248检视/开启

    在機構典藏中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回馈