淡江大學機構典藏:Item 987654321/115808
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 62805/95882 (66%)
造访人次 : 3941999      在线人数 : 1078
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/115808


    题名: Distillate Flux Enhancement of the Concentric Circular Direct Contact Membrane Distillation Module with Spiral Wired Flow Channel
    作者: Chii-Dong Ho;Luke Chen;Feng-Chi Tsai;Guan-Hong Lin;Jun-Wei Lim
    关键词: Concentric circular DCMD;Spiral wire channel;Desalination;Distillate flux enhancement
    日期: 2019
    上传时间: 2019-02-22 12:11:51 (UTC+8)
    摘要: The modeling equations for predicting distillate flux in the direct contact membrane distillation (DCMD) module with embedded spiral wire of various spiral wire pitches in concentric circular module were developed theoretically and verified experimentally. The temperature distributions, distillate flux and energy consumption of both concurrent- and countercurrent-flow operations were presented with the volumetric flow rate, inlet saline temperature, the spiral wire as parameters, and the experimental data was incorporated into the modeling equations to validate the theoretical predictions. A description of the average Nusselt number was made to evolve a correlating equation of heat transfer coefficients incorporating distillate flux and Reynolds numbers with the use of experimental data. The effects of operating and design parameters such as flow rate, inlet saline temperature and spiral wire pitch on the pure water productivity and power consumption under both concurrent- and countercurrent-flow operations were also analyzed.
    關聯: Journal of the Taiwan Institute of Chemical Engineers 94, p.70-80
    DOI: 10.1016/j.jtice.2017.09.052
    显示于类别:[化學工程與材料工程學系暨研究所] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    Distillate flux enhancement of the concentric circular direct contact membrane distillation module with spiral wired flow channel.pdf1490KbAdobe PDF1检视/开启
    index.html0KbHTML176检视/开启

    在機構典藏中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回馈