淡江大學機構典藏:Item 987654321/112288
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 62805/95882 (66%)
造訪人次 : 3936879      線上人數 : 835
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    淡江大學機構典藏 > 體育事務處 > 會議論文 >  Item 987654321/112288
    請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/112288


    題名: Comparison of Sensor Analysis for Swimming in Different Positions
    作者: Ku-Chen Huang, Chih-Ping Chu, Tung-Kuei Chiu, and Jui-Chen Chen
    關鍵詞: peak, wave period, sensory waveform
    日期: 2017-05-13
    上傳時間: 2017-12-06 02:10:13 (UTC+8)
    摘要: Using the sensor to monitor and to evaluate sports performance is a new trend in the future. The experimental results will be affected by the sampling frequency, placement of sensors, setting of the filter and instrumental correction, etc. This study is to explore the effect of different detection of position on swimming stroke. Methods: Three swimmers are participating in this research. Two inertial sensors will be placed on the right hand and forearm, upper and lower back and swimmers have to do a 50 meters freestyle. We have developed a system to read the data from sensors and to measure differences between the two placement locations. Results : (a) Peak value: the sensor data from hand higher than the forearm in freestyle x-axis and z-axis. The peak of the upper back X-axis was significantly higher than the lower back (p <.05). (b) Wave range: the sensor data from hand larger than the forearm in XYZ axis. (c) Wave periods: there are no significant differences between hand-forearm and upper-lower back locations. Conclusions: The sensor data obtained from hand location show a larger amplitude and peak value, and better waveform identification. It is important to place the sensor device on the hand for analyzing swimming stroke motion. Freestyle maximum peak is to show in the z-axis. So the relevant axis should choose carefully when analyzing the waveform data. The back location can provide balance and comfort, the data of upper back had a better effect on recognition, but there may have problems of unstable device placement and water resistance; the lower back sensor was close to body center, so it can examine body acceleration, speed, rotation, and frequency.
    關聯: Huang, K. C., Chu, C. P., Chiu, T. K. & Chen, J. C. (2017). Comparison of Sensor Analysis for Swimming in Different Positions.
    顯示於類別:[體育事務處] 會議論文

    文件中的檔案:

    沒有與此文件相關的檔案.

    在機構典藏中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回饋