淡江大學機構典藏:Item 987654321/110321
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 62805/95882 (66%)
造访人次 : 3923628      在线人数 : 526
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    淡江大學機構典藏 > 體育事務處 > 會議論文 >  Item 987654321/110321


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/110321


    题名: comparison of sensor analysis for swimming in different position
    作者: Huang, Ku-Chen;Chu, Chih-Ping;Chiu, Tung-Kuei;Chen, Jui-Chen
    关键词: peak;wave period;sensory waveform
    日期: 2017-05-13
    上传时间: 2017-06-02 02:10:13 (UTC+8)
    出版者: Taiwanese Institute of Knowledge Innovation
    摘要: Object:
    Using the sensor to monitor and to evaluate sports performance is a new trend in the future. The
    experimental results will be affected by the sampling frequency, placement of sensors, setting of the filter
    and instrumental correction, etc. This study is to explore the effect of different detection of position on
    swimming stroke.
    Methods:
    Three swimmers are participating in this research. Two inertial sensors will be placed on the right hand and
    forearm, upper and lower back and swimmers have to do a 50 m freestyle. We have developed a system to
    read the data from sensors and to measure differences between the two placement locations.
    Results :
    (a) Peak value: the sensor data from hand higher than the forearm in freestyle x-axis and z-axis. The peak of
    the upper back X-axis was significantly higher than the lower back (p <.05) (b) Wave range: the sensor data
    from hand larger than the forearm in XYZ axis. (c) Wave periods: there are no significant differences
    between hand-forearm and upper-lower back locations.
    Conclusions:
    The sensor data obtained from hand location show a larger amplitude and peak value, and better waveform
    identification. It is important to place the sensor device on the hand for analyzing swimming stroke motion.
    Freestyle maximum peak is to show in the z-axis. So the relevant axis should choose carefully when
    analyzing the waveform data.
    The back location can provide balance and comfort, the data of upper back had a better effect on
    recognition, but there may have problems of unstable device placement and water resistance; the lower back
    sensor was close to body center, so it can examine body acceleration, speed, rotation, and frequency.
    關聯: Proceedings of The 2017 IEEE International Conference on Applied System Innovation
    显示于类别:[體育事務處] 會議論文

    文件中的档案:

    没有与此文件相关的档案.

    在機構典藏中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回馈