淡江大學機構典藏:Item 987654321/106198
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 62830/95882 (66%)
造訪人次 : 4034115      線上人數 : 982
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library & TKU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    請使用永久網址來引用或連結此文件: https://tkuir.lib.tku.edu.tw/dspace/handle/987654321/106198


    題名: Detecting trypsin at liquid crystal/aqueous interface by using surface-immobilized bovine serum albumin
    作者: Cheng-Hao Chuang;Yi-Cheng Lin;You-Shuan Chen;Yu-Xun Chen;Chieh-Ming Chen;Hung Wei Shiu;Lo-Yueh Chang;Chia-Hao Chen;Chih-Hsin Chen
    關鍵詞: Liquid crystal-based biosensor;Bovine serum albumin;Trypsin;Scanning photoelectron microscopy
    日期: 2016-04-15
    上傳時間: 2016-04-22 13:24:06 (UTC+8)
    出版者: Elsevier
    摘要: We report a new mechanism for liquid crystal (LC)-based sensor system for trypsin detection. In this system, bovine serum albumin (BSA) was immobilized on gold grids as the enzymatic substrate. When the BSA-modified grid was filled with LC and immersed in the solution containing trypsin, the peptide bonds of BSA were hydrolyzed and peptide fragments were desorbed from the surface of gold grid, which disrupted the orientation of LC at the vicinity and resulted in a dark-to-bright transition of optical image of LCs. By using this mechanism, the limit of detection (LOD) of trypsin is 10 ng/mL, and it does not respond to thrombin and pepsin. Besides, the cleavage behavior on gold surfaces was directly visualized by the scanning photoelectron microscopy (SPEM), in particular for the chemical composition identification and element-resolved image. The loss of BSA fragments and the enhancement of Au photoelectron signal after trypsin cleavage were corresponding to the proposed mechanism of the LC-based sensor system. Because the signals reported by LC can be simply interpreted through the human naked-eye, it provides a simple method for fast-screening trypsin activity in aqueous solution.
    關聯: Biosensors and Bioelectronics 78, p.213–220
    DOI: 10.1016/j.bios.2015.11.049
    顯示於類別:[物理學系暨研究所] 期刊論文
    [化學學系暨研究所] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    Detecting trypsin at liquid crystal_aqueous interface by using surface-immobilized bovine serum albumin.pdf4506KbAdobe PDF3檢視/開啟
    index.html0KbHTML431檢視/開啟

    在機構典藏中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library & TKU Library IR teams. Copyright ©   - 回饋