    題名: Comparison of low-pressure reverse osmosis filtration and polyelectrolyte-enhanced ultrafiltration for the removal of Co and Sr from nuclear plant wastewater
    作者: Dang, Thi Thu Hien;Li, Chi-Wang;Choo, Kwang-Ho
    關鍵詞: Membrane filtration;Polyelectrolyte;Complexation;Metal rejection;Fouling
    日期: 2015-11-13
    上傳時間: 2016-04-22 13:15:08 (UTC+8)
    出版者: Pergamon Press
    摘要: Volume reduction and the concentration of long-lived radioactive species are critical issues for the management of liquid low-level radioactive waste. This study investigated and compared the performances of low-pressure reverse osmosis (LPRO) and polyelectrolyte-enhanced ultrafiltration (PEUF) for the removal of target metals (Co and Sr) from simulated low-level radioactive waste. The effects of dosage and types of chelating polymers, such as polyacrylic acid (PAA) and polyethylenimine (PEI), were evaluated at acidic and neutral pH levels. The metal removal efficiencies by precipitation at acidic pH (4.5) and neutral pH (6.5) were marginal. The addition of PAA to LPRO had no effect on metal removal, but had a negative impact on membrane permeability, particularly at acidic pH levels. The LPRO itself already achieved sufficient metal rejection; therefore, the addition of PAA only caused fouling. In contrast, the PAA dosage and solution pH governed the metal rejection in PEUF. Deprotonated PAA molecules bound to metal ions, but the distribution of PAA species had no significant impact on flux decline. The PEUF with PEI exhibited almost no pH dependency in metal removal, but showed metal-specific removal behaviors. The PEUF with PAA achieved metal removal as high as LPRO, with relatively high water permeability.
    關聯: Separation and Purification Technology 157, pp.209-214
    DOI: 10.1016/j.seppur.2015.11.019